RelaysProduct features:1. Heating mode 'H' :When the detection temperature is less than or equal to the set temperature-return temperature, the relay turns on and the heating equipment starts to work.When the detection temperature is greater than or equal to the set temperature, the relay is disconnected and the heating equipment stops working.2. Cooling mode 'C' :When the detection temperature set temperature + temperature, relay on, refrigeration equipment starts to work;When the detection temperature is less than or equal to the set temperature, the relay is disconnected and the refrigeration equipment stops working.3. High temperature alarm function ALA:When the actual temperature is greater than or equal to the alarm temperature, the system will start the sound and light alarm, and disconnect the relay, and any key will stop the sound and light;4. Delay start OPH:When a normal heating or cooling work is completed, the system starts T, only when TOPH, the system can carry out the next round of heating or cooling work;5 temperature correction function OFE(-10.0~10.0) :If the system works for a long time, there may be deviations. Through this function correction, the actual temperature = measured temperature + calibration value;6. Relay enable (default enabled) :If the relay is disabled, the relay remains disconnected.7. Restore Settings:Press STOP and SET for 3S to restore Settings;Working mode/Setting temperature/return temperature setting:1. In the running interface, press the SET key to enter the quick setting interface2. After entering the quick setting interface, press the SET key to switch the parameters to be SET (working mode/setting temperature/return temperature);3. Press the UP DOWN key to modify parameter values.4. Long press SET for more than 3S or for 6S without any key operation, exit the quick setting interface and save parameters;Alarm temperature/delay start setting/temperature correction:1. In the running interface, hold down SET for more than 3s to enter the parameter setting interface;2. After entering the parameter setting interface, press the SET key to switch the parameters to be SET (alarm temperature/delay start setting/temperature correction);3. Press the UP DOWN key to modify parameter values.4. Long press SET for 3S or for 6S without any key operation, exit the parameter setting interface and save the parameters;How to enable the high temperature alarm (off by default):Enter the parameter setting interface, switch to the alarm parameter ALA interface, press STOP button to turn on or off the high temperature alarm function; If the high temperature alarm function is turned off, ALA displays "----" to remind;How to enable delayed startup (off by default):Enter the parameter setting interface, switch to the alarm parameter OPH interface, press STOP button to turn on or off the high temperature alarm function; If the high temperature alarm function is disabled, the OPH displays "----" to remind.==========Model Number : XY-DT01 Application : OtherCondition : Type : Voltage RegulatorOrigin : Mainland
| Model | RTOZWC |
|---|---|
| Brand Name | RTOZWC |
| Part Number | RTOZWC |
| Manufacturer | RTOZWC |
If you notice any omissions or errors in the product information on this page, please use the correction request form below.
Correction Request Form